{"id":6338,"date":"2020-11-16T15:05:16","date_gmt":"2020-11-16T07:05:16","guid":{"rendered":"https:\/\/tommykwan.com\/blog\/?p=6338"},"modified":"2020-11-16T21:09:43","modified_gmt":"2020-11-16T13:09:43","slug":"testing-examination-and-inspection-of-lifting-appliance","status":"publish","type":"post","link":"https:\/\/tommykwan.com\/blog\/occupational-health-and-safety-osh\/legislative-context-in-ohs\/testing-examination-and-inspection-of-lifting-appliance\/","title":{"rendered":"Testing, Examination and Inspection of Lifting Appliance"},"content":{"rendered":"[Ref\u00a0<a href=\"https:\/\/www.elegislation.gov.hk\/hk\/cap59J!en-zh-Hant-HK?INDEX_CS=N&amp;xpid=ID_1438403506188_002\" target=\"_blank\" rel=\"noopener noreferrer\">Cap.59J<\/a>]\n<blockquote><p>\u6ce8\u610f: \u8d77\u91cd\u6a5f\u68b0 (<a href=\"https:\/\/tommykwan.com\/blog\/occupational-health-and-safety-osh\/legislative-context-in-ohs\/whats-crane-%e8%b5%b7%e9%87%8d%e6%a9%9f-hoist-%e5%90%8a%e9%87%8d%e6%a9%9f-lifting-appliance-%e8%b5%b7%e9%87%8d%e6%a9%9f%e6%a2%b0-and\/\" target=\"_blank\" rel=\"noopener noreferrer\">lifting appliance<\/a>) \u4f7f\u7528\u524d\u5148\u6e2c\u8a66\u53ca\u6aa2\u9a57\u662f <a href=\"https:\/\/tommykwan.com\/blog\/occupational-health-and-safety-osh\/whats-owner-in-fiu-la-lg-r\/\" target=\"_blank\" rel=\"noopener noreferrer\">Owner<\/a> (\u64c1\u6709\u4eba) \u7684\u8cac\u4efb!<\/p><\/blockquote>\n<p>According to <strong>Cap 59 J<\/strong> :<\/p>\n<blockquote><p><strong>5.<\/strong> Lifting appliances to be <strong>tested and examined<\/strong> prior to use (\u4f7f\u7528\u524d\u5148\u6e2c\u8a66\u53ca\u6aa2\u9a57)<\/p>\n<ol>\n<li>The owner of a <span style=\"color: #ff0000;\"><strong>lifting appliance<\/strong><\/span> shall ensure that it is not used unless it has been thoroughly examined by a competent examiner at least once in the preceding<span style=\"color: #ff0000;\"><strong> 12 months<\/strong><\/span>, <strong>and<\/strong> a <strong>certificate<\/strong> (<span style=\"color: #ff0000;\"><strong>form 5<\/strong><\/span>) in the approved form in which the<strong><a href=\"https:\/\/tommykwan.com\/blog\/occupational-health-and-safety-osh\/legislative-context-in-ohs\/competent-examiner-%e5%90%88%e8%b3%87%e6%a0%bc%e6%aa%a2%e9%a9%97%e5%93%a1-v-s-competent-person-%e5%90%88%e8%b3%87%e6%a0%bc%e7%9a%84%e4%ba%ba\/\" target=\"_blank\" rel=\"noopener noreferrer\"> competent examiner<\/a><\/strong> has made a statement to the effect that it is in safe working order has been obtained.<\/li>\n<li>The owner of a<strong> lifting appliance<\/strong> <em>other than a crane, crab or winch<\/em> shall ensure that it is not used unless it has been tested and thoroughly examined by a competent examiner in the manner prescribed in the<strong> First Schedule<\/strong>,<strong> and<\/strong> a <strong>certificate <\/strong>(<span style=\"color: #ff0000;\"><strong>form 4<\/strong><\/span>) in the approved form in which the competent examiner has been obtained.<\/li>\n<li>The owner of any <span style=\"color: #ff0000;\"><strong>crane, crab or winch<\/strong> <\/span>shall ensure that it is not used unless during the preceding <span style=\"color: #ff0000;\"><strong>4 years<\/strong><\/span> it has been tested and thoroughly examined by a <strong><a href=\"https:\/\/tommykwan.com\/blog\/occupational-health-and-safety-osh\/legislative-context-in-ohs\/competent-examiner-%e5%90%88%e8%b3%87%e6%a0%bc%e6%aa%a2%e9%a9%97%e5%93%a1-v-s-competent-person-%e5%90%88%e8%b3%87%e6%a0%bc%e7%9a%84%e4%ba%ba\/\" target=\"_blank\" rel=\"noopener noreferrer\"> competent examiner<\/a><\/strong>\u00a0in the manner prescribed in the First Schedule,<strong> and<\/strong> a <strong>certificate<\/strong> (<span style=\"color: #ff0000;\"><strong>form 3<\/strong><\/span>)\u00a0in the approved form in which the competent examiner has made a statement to the effect that it is in safe working order has been obtained.<\/li>\n<li>If any <strong>lifting appliance<\/strong> of the description mentioned in paragraph (1) or (2) has been thoroughly examined or tested and thoroughly examined, as the case may be, in accordance with those paragraphs but has since<strong> undergone substantial repair, re-erection, failure, overturning or collapse,<\/strong> the owner of the lifting appliance shall ensure that it is not <strong>used unless it has been further tested and thoroughly examined by a competent examiner<\/strong>, and there has been obtained from him in respect of the test and thorough examination a <strong>certificate <\/strong>(<strong>form 4<\/strong>)\u00a0in the approved form in which he has made a statement to the effect that it is in safe working order.<\/li>\n<li>If any <strong>crane, crab or winch<\/strong> has been tested and thoroughly examined but has since<strong> undergone substantial repair, re-erection, failure, overturning or collapse<\/strong>, the owner of the crane, crab or winch shall ensure that it is<strong> not used unless it has been further tested and thoroughly examined by a competent examiner<\/strong>, and there has been obtained from him in respect of the test and thorough examination a <strong>certificate\u00a0<\/strong>(<strong>form 3<\/strong>) in the approved form in which he has made a statement to the effect that it is in safe working order.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p><strong>7A.<\/strong> Periodical<strong> inspection<\/strong> by a competent person (\u7531\u5408\u8cc7\u683c\u7684\u4eba\u5b9a\u671f\u6aa2\u67e5)<br \/>\nThe owner of a <strong>lifting appliance<\/strong> shall ensure that it is not used unless it has been inspected within the preceding<span style=\"color: #ff0000;\"><strong> 7 days<\/strong><\/span> by a <a href=\"https:\/\/tommykwan.com\/blog\/occupational-health-and-safety-osh\/legislative-context-in-ohs\/competent-examiner-%e5%90%88%e8%b3%87%e6%a0%bc%e6%aa%a2%e9%a9%97%e5%93%a1-v-s-competent-person-%e5%90%88%e8%b3%87%e6%a0%bc%e7%9a%84%e4%ba%ba\/\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>competent person<\/strong><\/a> and the competent person has given the owner a <strong>certificate <\/strong>(<span style=\"color: #ff0000;\"><strong>form 1<\/strong><\/span>) in the approved form in which he has made a statement to the effect that the lifting appliance is in safe working order.<\/p><\/blockquote>\n<h5><strong>Summary<\/strong><\/h5>\n<ul>\n<li><strong>Form 5<\/strong> &#8211; Cap 59J 5 (1) \u6307\u51fa: <strong>\u00a0LA<\/strong> \u6bcf<strong>12\u500b\u6708<\/strong>\u5c31\u8981\u7531<strong>CE (\u5408\u8cc7\u683c\u6aa2\u9a57\u54e1 &#8211; RPE)\u00a0<\/strong>\u6839\u64da Cap 59J &#8220;First Schedule&#8221; \u53bb\u505a <strong>test and examination<\/strong> \u4e26\u4e14\u8981\u6709 certificate \u53bb\u8ff0\u660e\u8a72\u8d77\u91cd\u6a5f\u68b0\u8655\u65bc\u5b89\u5168\u64cd\u4f5c\u72c0\u614b<\/li>\n<li><strong>Form 4<\/strong> &#8211; Cap 59J 5 (2) \u6307\u51fa: <strong>LA<\/strong>\u00a0<em>other than a crane, crab or winch<\/em>\u00a0\u4f7f\u7528\u524d\u8981\u6839\u64da Cap 59J &#8220;First Schedule&#8221; \u53bb\u505a <strong>test and examination<\/strong> \u4e26\u4e14\u8981\u6709 certificate \u53bb\u8ff0\u660e\u8a72\u8d77\u91cd\u6a5f\u68b0\u8655\u65bc\u5b89\u5168\u64cd\u4f5c\u72c0\u614b\n<ul>\n<li>Cap 59J 5 (4) \u6307\u51fa: <strong>LA<\/strong> \u6bcf\u7576\u91cd\u5927 (substantial) \u4fee\u7406 (repair)\u3001\u91cd\u65b0\u67b6\u8a2d (re-erection)\u3001\u5931\u9748 (failure)\u3001\u7ffb\u5012 (overturning) \u6216 \u5012\u584c (collapse) \u5c31\u8981\u7531CE \u53bb\u505atest and examination \u540c \u7c3d\u756a <strong>Form 4<\/strong><\/li>\n<\/ul>\n<\/li>\n<li><strong>Form 3<\/strong>\u00a0&#8211; Cap 59J 5 (3) \u6307\u51fa: <strong> crane<\/strong>,<strong> crab <\/strong>or<strong> winch<\/strong>\u00a0\u6bcf<strong>4\u5e74<\/strong>\u5c31\u8981\u7531<strong>CE (\u5408\u8cc7\u683c\u6aa2\u9a57\u54e1 -RPE)<\/strong> \u6839\u64da Cap 59J &#8220;First Schedule&#8221; \u53bb\u505a <strong>test and examination<\/strong> \u4e26\u4e14\u8981\u6709 certificate \u53bb\u8ff0\u660e\u8a72\u8d77\u91cd\u6a5f\u68b0\u8655\u65bc\u5b89\u5168\u64cd\u4f5c\u72c0\u614b\n<ul>\n<li>Cap 59J 5 (5) \u6307\u51fa: , <strong>crane<\/strong>,<strong> crab <\/strong>or<strong> winch<\/strong> \u6bcf\u7576\u91cd\u5927 (substantial) \u4fee\u7406 (repair)\u3001\u91cd\u65b0\u67b6\u8a2d (re-erection)\u3001\u5931\u9748 (failure)\u3001\u7ffb\u5012 (overturning) \u6216 \u5012\u584c (collapse) \u5c31\u8981\u7531CE \u53bb\u505atest and examination \u540c \u7c3d\u756a <strong>Form 3<\/strong><\/li>\n<\/ul>\n<\/li>\n<li><strong>Form 1<\/strong> &#8211; Cap 59J 7A \u6307\u51fa: LA (\u5305\u62ec crane, crab or winch) \u6bcf<strong>7<\/strong><b>\u65e5<\/b>\u5c31\u8981\u7531<strong>CP (\u5408\u8cc7\u683c\u7684\u4eba) \u505ainspection (\u6aa2\u67e5)<\/strong>\u4e26\u4e14\u8981\u6709 certificate \u53bb\u8ff0\u660e\u8a72\u8d77\u91cd\u6a5f\u68b0\u8655\u65bc\u5b89\u5168\u64cd\u4f5c\u72c0\u614b<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>Notes:<\/p>\n<p>for<strong> form 2<\/strong>, please refer to<a href=\"https:\/\/tommykwan.com\/blog\/occupational-health-and-safety-osh\/legislative-context-in-ohs\/legislative-context-in-cap-59j-related-to-crane\/\" target=\"_blank\" rel=\"noopener noreferrer\"> 7E (2) &amp; (3)<\/a> ;<\/p>\n<p>for <strong>form 6<\/strong>, please refer to 18(1)(d) ;<\/p>\n<p>for<strong> form 7<\/strong>, please refer to 18(1)(e) ;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[Ref\u00a0Cap.59J] \u6ce8\u610f: \u8d77\u91cd\u6a5f\u68b0 (lifting appliance) \u4f7f\u7528\u524d\u5148\u6e2c\u8a66\u53ca\u6aa2\u9a57\u662f Owner (\u64c1\u6709\u4eba) \u7684\u8cac\u4efb! According to Cap 59 J : 5. Lifting appliances to be tested and examined prior to use (\u4f7f\u7528\u524d\u5148\u6e2c\u8a66\u53ca\u6aa2\u9a57) The owner of a lifting appliance shall ensure that it is not used unless it has been thoroughly examined by a competent examiner at least once in the<a class=\"read-more \" href=\"https:\/\/tommykwan.com\/blog\/occupational-health-and-safety-osh\/legislative-context-in-ohs\/testing-examination-and-inspection-of-lifting-appliance\/\" title=\"Read More\"> <span class=\"button default\">Read More<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[36],"tags":[],"class_list":["post-6338","post","type-post","status-publish","format-standard","hentry","category-legislative-context-in-ohs"],"_links":{"self":[{"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/posts\/6338","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/comments?post=6338"}],"version-history":[{"count":22,"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/posts\/6338\/revisions"}],"predecessor-version":[{"id":6363,"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/posts\/6338\/revisions\/6363"}],"wp:attachment":[{"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/media?parent=6338"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/categories?post=6338"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tommykwan.com\/blog\/wp-json\/wp\/v2\/tags?post=6338"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}